What function does tower hang track ground have, what is specific requirement?

L46A1 Mast Section

Tower grounding can not only serve as a repeated grounding of the TN-S connection zero protection system for temporary power engineering on the spot, but also serve as a lightning protection grounding for the tower crane itself.
In order to fully reflect the dual significance of Tower grounding, tower grounding should meet the following requirements:
(1) The power frequency earth resistance of the grounding device shall not exceed 10 Ω.
(2) The grounding device shall be electrically connected to the tower suspension track in two places.